水系统管线
Water System Piping
管线安装
Piping Installation
管线,连接件,和阀门应该按照(图6的)安装图进行安装。如果室内安装区域可能出现冰冻温度,则水管线必须加装保温层保护。
Piping, fittings, and valves should be installed
according to the installation drawing (Figure 6). If the indoor installation
area is subject to freezing temperatures, the water piping must be protected
by insulation.
供水压力不能超过热水器工作压力的80%. 热水器的工作压力标注在热水器的参数板上。如果出现超压这种情况,则可能需要在冷水供应管道上安装带旁路的限压阀。为了保持相同的热水和冷水压力,这个装置应该安装在整个室内住宅的供水管道上。
Water supply pressure should not exceed 80% of
the working pressure of the water heater. The working pressure is stated
on the water heater's data plate. If this occurs a pressure limiting valve
with a bypass may need to be installed in the cold water supply line.
This should be placed on the supply to the entire house in order to maintain
equal hot and cold water pressures.
重要提示:不要在热水器的水连接件上加热,因为它们可能包含非金属部件。如果需要采用焊接连接方法,要先将管道焊接在连接器上,然后再将连接器连接在热水和冷水接头上。
Important: Heat cannot be applied
to be water fittings on the heater as they may contain nonmetallic parts.
If solder connections are used, solder the pipe to the adapter before
attaching the adapter to the hot and cold water fittings.
重要提示:务必使用高等级的连接部件,确保所有连接件连接紧固。
Important: Always use a good
grade of joint compound and be certain that all fittings are drawn up
tight.
- 按照图6所示安装水管线和连接件。将冷水供水管道(3/4 NPT英寸)连接到标注“C”的接头上。将热水管道(3/4 NPT英寸)连接到标注“H”的接头上。
Install the water piping and fittings as shown
in Figure 6. Connect the cold water supply (3/4 NPT) to the fitting
marked “C”. Connect the hot water supply (3/4 NPT) to the fitting marked
“H”.
重要提示:有些型号的热水器可能包含节能的热疏水器,以防止热水在管道内环流。不要拆卸这些内置件。
Important: Some
models may contain energy saving heat traps to prevent the circulation
of hot water within the pipes. Do not remove these inserts.
- 建议在热水‘和冷水管线上安装管接头,以方便热水器的维修或更换。
The installation of unions in both the hot and
cold water supply lines is recommended for ease of removing the water
heater for service or replacement.
- 本热水器制造商建议在家庭热水管线上如图7和8所示安装调节阀。这种阀门通过将冷水与热水的混合降低使用点的热水温度,并随时提供所需热水。有关资料请咨询有执照的管道工或当地管道主管部门。
The manufacturer of this water heater recommends
installing a tempering valve in the domestic hot water line as shown
in Figures 7 and 8. These valves reduce the point-of-use temperature
of the hot water by mixing cold and hot water and are readily available.