美国进口
Imported from USA

住宅小区控制阀- ZoneTrol™ II
Residential Controls - ZoneTrol™ II


美国贝尔-高赛特
Bell & Gossett

The next generation of zone controllers from Bell & Gossett brings 21st century technology to residential controls.

ZoneTrol™ II provides DHW priority timer, post purge function and pump exercise into an economical and user-friendly package.

With optional outdoor reset controls, the ZoneTrol II is a natural fit with today's green building strategies. Your modern hydronic systems deserve a modern controller. Description

Xylem's Bell & Gossett ZoneTrol II is a ready-to-install controller for hydronic circulators in residential and light commercial applications. All ZoneTrol II controllers are UL and cUL listed and feature multi-function LEDs that are visible without removing the cover for easy start-up and troubleshooting. All units are compatible with analog and digital 24 VAC thermostats, including "power stealing" designs.

The multi-zone controllers feature an advanced microprocessor design that provides domestic hot water (DHW) priority & timer, pump exercise and a post purge timer without the need for add-on circuit boards or modules. Four and six zone controllers are field expandable for up to 18 pumps and are available with integrated, pre-wired boiler reset or mix reset controllers. Units with reset controllers include all necessary sensors.

Optional Features (4 and 6 zone controllers only)

  • Boiler Reset: Incorporates a pre-wired integral boiler reset controller into the ZoneTrol II enclosure. Reset controller cycles the burner to maintain the optimum system supply temperature relative to the outdoor air temperature. Warm weather shutdown functionality can be activated to prevent system operation above a user-selectable outdoor temperature threshold. All necessary sensors are included.
  • Mixing Reset: For use on hydronic systems incorporating a variable speed injection pump. Incorporates a pre-wired integral mixing reset controller into the ZoneTrol II enclosure. Mixing Reset controller varies the speed of the injection pump to maintain optimum radiant loop temperature relative to the outdoor air temperature. The boiler return temperature is also monitored to ensure that the appropriate minimum water temperature is not violated. Warm weather shutdown functionality can be activated to prevent system operation above a user-selectable outdoor temperature threshold. All necessary sensors are included.

APPLICATIONS:

  • Controller for hydronic circulators in residential and light commercial applications

Features and Benefits

  • Post Purge Timer: Circulator(s) will continue to run for 90 seconds after thermostat opens and allows additional extraction of BTUs from high mass boilers. User adjustable settings are OFF and ON.
  • Exercise: Runs each circulator for 10 seconds after each 72 hours of inactivity. User adjustable settings are ON and OFF.
  • Expandability: 4 and 6 zone controllers can easily be connected via an RJ-11 cable to accommodate systems consisting of up to 18 circulators.
  • Five-year Warranty

Bell & Gossett offers several useful engineering tools for easy sizing of every area of a building. Simple to navigate software gives you accurate information and up-to-date documentation downloadable straight into your submittal package.

Some tools require a registered account: New User Registration | Existing User Password Help

ESP-Design Plus Bell & Gossett: Multi-Stage, Pressure Booster Packages, Wastewater, Vertical Turbines
ESP-Plus Bell & Gossett Pump Selection: Circulators, End Suction, Closed-Coupled, Inline, Double Suction
ESP-Tanks Bell & Gossett Compression/Expansion Tanks and Accessories (downloadable app)
ESP-Thermal Bell & Gossett Gasket Plate & Frame and, Brazed Plate Heat Exchangers
ESP-UTUBE Bell & Gossett U-Tube Heat Exchangers
ESP-Parts Parts Selection
Steam-2000 Steam 2000 Selection
Steam-1140 Series 1140 Steam Service Regulators
Water-1140 Series 1140 Water Service Regulators
Steam-Traps Steam Traps Selection
CAD Drawings CAD Drawings
System Syzer System Syzer (available online, PC download, and iOS app)
System Syzer Psychrometry System Sizing related to coil cooling (link downloads .exe file)
Steam-Pipe Steam Pipe Sizing
Steam-Loss Steam Loss Through Failed Trap
Flash-Steam Flash Steam Sizing
Condensate-Pipe Condensate Pipe Sizing
Mobile Catalog iOS iPhone & iPad Mobile Product Catalog
Mobile Catalog Android Android Device Mobile Product Catalog